M242 Disassembly

1. REMOVE DAMPER FLUID.

a. Place damper housing assembly (1) on clean work surface.

b. Press recoil damper rod (2) until second hole (3) in indicator rod (4) can be seen or insert lock pin (5) in first hole (6) and pull indicator rod (4) out.

c. Insert a lock pin (5) in second hole (3) of indicator rod (4).

Spring support threads may be damaged if clamped in a vise. Clamp vise jaw caps only on support flats.

d. Place damper housing assembly (1) in vise with vise jaw caps with indicator rod (4) at bottom.